EV Battery Testing Chiller – KRY Variable Frequency Series

Temperature control in the testing process of new energy vehicle components.

The equipment can meet the requirements of direct cooling or direct heating for battery pack and electric vehicle testing. The device is mainly used for testing the cooling and heating capacity of the batteries. It can adopt a variable frequency compressor with adjustable output; variable frequency fan with adjustable speed and heat dissipation capacity. Combined with high precision temperature, pressure and flow sensors. It can also calculate heat transfer capacity in real time and automatically recover and add refrigerant. Can accommodate battery packs of different sizes.

The testing object is connected to a testing adapter; component cooling and heating test is conducted by ethylene glycol plus water mixture.

The test unit needs to go through a specific temperature range curve and record the temperature change. The temperature usually ranges from -40degC to 100degC (expandable up to 150degC)

Overview:

  • Working Temperature Range: -40degC to +150degC
  • Temperature/pressure/flow can be independently controlled
  • The temperature of antifreeze ranges from -40degC to +100degC (expandable to +150degC) with a very steep temperature gradient.
  • Different application related models like – One machine for two groups control; one machine for six groups control; Variable Frequency vortex compressor.
  • Variable frequency series models: Can adopt a variable frequency vortex compressor, the operating speed is automatically adjusted according to actual needs, providing the required cooling capacity. Compared with traditional fixed frequency compressors, it significantly reduces energy consumption and improves energy efficiency performance.
  • Constant power output function for both hot and cold.
  • LNEYA PLC control with 7-inch colour large screen and comprehensive multifunctional image display of important data information.
  • Relevant operational status data can be continuously monitored and visualized on the screen. Can independently control one to multiple flow channels where each group can be independently set.
KRY Variable Frequency Series
Model KRYZ-475/KRYZ-475W KRYZ-4A15W KRYZ-4A25W
Temp Range -40°C to +100°C
Temp Control Accuracy ±0.1°C ±0.1°C ±0.1°C
Temp Feedback Pt100 Pt100 Pt100
Temp Display 0.01k 0.01k 0.01k
Flow Rate Output 1 – 25 L/min 1 – 25 L/min 1 – 25 L/min
Traffic Description When the temperature is below -30°C, the flow control is within 80% of the maximum value
Flow Rate Accuracy ±0.1 L/min ±0.1 L/min ±0.1 L/min
Pressure Display The unit can control the flow individually or separately. Need to control different solutions at the same time (customized)
Heating Power 7.5kW 15kW 25kW
Cooling Capacity (100°C) 7.5kW 15kW 25kW
Cooling Capacity (20°C) 7.5kW 15kW 25kW
Cooling Capacity (0°C) 7.5kW 15kW 25kW
Cooling Capacity (-20°C) 4.5kW 10kW 16kW
Cooling Capacity (-35°C) 1.8kW 4kW 6.5kW
Compressor Emerson Copeland
Throttle Type Electronic expansion valve
Oil Separator Emerson
Dry Filter Danfoss
Evaporator Plate heat exchanger
Circulation Pump Magnetic driven pump
Input Display 7-inch color touch screen PLC controller
Program Editor 5 programs, each program can edit 40 steps
Communication Modbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet interface TCP/IP protocol
Safety Protection With self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection device, high temperature protection, sensor fault protection and other safety functions
Closed Circulation System The whole system is a fully closed system, there will be no oil mist at high temperature, the system in operation will not because of high temperature pressure rise, low temperature automatically add heat conduction medium.
Refrigerant R404A/R507C
Connection Size ZG3/4 ZG3/4 ZG3/4
Water-Cooled At 20°C 2500L/H ZG3/4 4000L/H ZG1 6000L/H DN32
Condenser (W) Special attention should be paid to the use of plate heat exchangers in the water circuit equipment condenser of this series of products. Water supply from a chiller or low hardness tap water requires a water purification filter
Condenser (A) Microchannel heat exchanger
Power 380V50HZ 14kW 25kW 38kW
Dimension (cm) 55*85*175 70*100*175 80*120*185
Weight 280kg 360kg 620kg
Optional The size external circulation pipe line is DN15 or DN20, do not throttle, which will increase the circulation pump load, pipe need to be insulated, and adopt rubber and plastic insulation pipe which can afford high temp, liquid low level protection
Case Material Cold rolled steel powder coating (standard color 7035)
KRY Variable Frequency Series
Model KRYZ-475W/2T KRYZ-4A15W/2T KRYZ-4A25W/2T
Temp Range -40°C to +100°C
Temp Control Accuracy ±0.1°C ±0.1°C ±0.1°C
Temp Feedback Pt100 Pt100 Pt100
Temp Display 0.01k 0.01k 0.01k
Flow Rate Output 1 – 25 L/min 1 – 25 L/min 1 – 25 L/min
Traffic Description When the temperature is below -30°C, the flow control is within 80% of the maximum value
Flow Control Accuracy/Group ±0.1 L/min ±0.1 L/min ±0.1 L/min
Number of Fluid Output Groups 2 groups 2 groups 2 groups
Pressure Control/Group 0.2bar – 2.5bar 0.2bar – 2.5bar 0.2bar – 2.5bar
Flow Pressure Description The unit can control the flow individually or separately. Need to control different solutions at the same time (customized)
Heating Power 7.5kW*2 10kW*2 15kW*2
Cooling Capacity (100°C) 7.5kW*2 15kW*2 25kW*2
Cooling Capacity (20°C) 7.5kW*2 15kW*2 25kW*2
Cooling Capacity (0°C) 7.5kW*2 15kW*2 25kW*2
Cooling Capacity (-20°C) 4.5kW*2 8.5kW*2 14kW*2
Cooling Capacity (-35°C) 1.8kW*2 4kW*2 6.5kW*2
Compressor Emerson Copeland
Throttle Type Electronic expansion valve
Oil Separator Emerson
Dry Filter Danfoss
Evaporator Plate heat exchanger
Circulation Pump Magnetic driven pump
Input Display 7-inch color touch screen PLC controller
Program Editor 5 programs, each program can edit 40 steps
Communication Modbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet interface TCP/IP protocol
Safety Protection With self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection device, high temperature protection, sensor fault protection and other safety functions
Closed Circulation System The whole system is a fully closed system, there will be no oil mist at high temperature, the system in operation will not because of high temperature pressure rise, low temperature automatically add heat conduction medium.
Refrigerant R404A/R507C/R125/N40 All four refrigerants are available
Connection Size ZG3/4 ZG3/4 ZG3/4
Water-Cooled At 20°C 4000L/H ZG1 8000L/H DN32 12000L/H DN40
Condenser (W) Special attention should be paid to the use of plate heat exchangers in the water circuit equipment condenser of this series of products. Water supply from a chiller or low hardness tap water requires a water purification filter
Condenser (A) Microchannel heat exchanger
Power 380V50HZ 28kW 45kW 70kW
Dimension (cm) 80*120*185 100*150*185 200*145*205
Weight 660kg 850kg 1350kg
Standard Automatic antifreeze system, automatic liquid recovery system
Optional 220V 60HZ three-phase, 460V 60HZ three-phase temperature, extended to -40°C to +135°C
Optional The size external circulation pipe line is DN15 or DN20, do not throttle, which will increase the circulation pump load, pipe need to be insulated, and adopt rubber and plastic insulation pipe which can afford high temp, liquid low level protection
Case Material Cold rolled steel powder coating (standard color 7035)