Glass Overhead Assembly

1,500,000.00

Glass overhead assemblies are executed mainly at production levels on glass lined reactors, SS reactors or Hastelloy reactors. The configuration depends upon the reaction applications. We are capable of manufacturing glass columns up to DN800 size, Shell & tube heat exchanger up to an area of 25 sq.m and receiver & feed vessels up to 300L spherical geometry.

Get a Quote
Category:

Specifications

DESCRIPTION JE-OA-63 JE-OA-160 JE-OA-250 JE-OA-500 JE-OA-1000 JE-OA-2500 JE-OA-5000 REMARKS / DETAILED DESCRIPTION
Glass Feed Vessel 10L 20L 50L 50L 100L 100L X 2 Nos. 100L X 2 Nos. Option available for twin feed vessels, cylindrical / spherical vessels as per client’s requirement. Vessels will be graduated and calibrated.
Glass Receiver Vessel 10L 20L 50L 50L 100L 100L X 2 Nos. 100L X 2 Nos. Option available for twin feed vessels, cylindrical / spherical vessels as per client’s requirement. Vessels will be graduated and calibrated.
Glass Vapour Line DN100 DN100 DN150 DN250 DN250 DN300 DN300 Vapor column can be with / without packing as per client’s requirement.
Glass Primary Condenser DN150-C; 1 sq.m DN150-C; 1.5 sq.m DN225-C; 2.5 sq.m DN225-S; 6 sq.m DN225-S; 10 sq.m DN300-S; 16 sq.m DN300-S; 25 sq.m S – Shell & Tube Type
C – Coil Type
Glass Secondary Condenser DN80-C; 0.3 sq.m DN100-C; 0.5 sq.m DN100-C; 0.5 sq.m DN150-C; 1 sq.m DN150-C; 1.5 sq.m DN150-S; 3 sq.m DN150-S; 4 sq.m
Glass Internal Process Pipelines DN25 DN25 DN40 / DN25 DN40 / DN25 DN40 / DN25 DN40 / DN25 DN40 / DN25 Condensate outlet & reflux line
Hardware – Plastic flanges, Inserts , SS Nuts, bolts, washers and springs SET SET SET SET SET SET SET Plastic flanges used as per DIN standard. Option available for SS-304 / SS-316 flanges too.
Structure – Main Frame Suitable size structure to be selected. MOC options of stainless steel and mild steel with epoxy coating available.
Rupture Disc DN40 / DN50 DN40 / DN50 DN40 / DN50 DN40 / DN50 DN40 / DN50 DN40 / DN50 DN40 / DN50 Suitable to withstand vacuum and burst pressure rating of 0.6 bar @ 100 DegC.
Temperature Sensors (Optional) 3 temp points considered with indication on the panel – vapor, product and vent. Sensor of reputed make (FLP enclosure) Duplex 3 wire Class A PT100 sensors to be used.
Documentation (Optional) SET SET SET SET SET SET SET Complete set of documentation and certifications will be provided.
These are general specifications, it may deviate as per client’s requirement or at detailing stage.